S300-M13C3-M20-31 Part no.: 63000303
Safety locking device
หมวดหมู่ : Safety technology ,  Safety locking device , 
แบรนด์ : Leuze
Share
คุณสมบัติ
Basic data
Series S300
Functions
Functions Integration in control circuits up to category4 in accordance with EN ISO 13849-1
Locking device without guard interlocking according to EN ISO 14119
Characteristic parameters
Mission time 20 years, EN ISO 13849-1
B10d 40,000,000 number of cycles
Electrical data
Usage category at DC 13 Ue / Ie: 24 V / 6 A, 125 V / 1.1 A, 250 V / 0.4 A, EN 60947-5-1
Usage category at AC 15 Ue / Ie: 250 V / 6 A, 400 V / 4 A, 500 V / 1 A, EN 60947-5-1
Contact allocation 2NC + 1NO
Contact opening Force-fit
Short circuit protected 500 V, 10 A, type aM, IEC 60269-1
Contact protection Earthing
Performance data
Rated insulation voltage 400 V AC, 500 V DC
Conventional thermal current, max. 10 A
Connection
Number of connections 1 Piece(s)
Number of cable entries 3 Piece(s)
Connection 1
Function Contact connection
Type of connection Terminal
Type of terminal Screw terminal
No. of pins 6 -pin
Cable properties
Connection cross sections 1 x 0.34 mm² to 2 x 1.5 mm², wire
Mechanical data
Design Cubic
Dimension (W x H x L) 56 mm x 33 mm x 88 mm
Housing material Metal
Metal housing ZAMAK
Electrical contact material Silver alloy
Net weight 303 g
Housing color Gray
Type of fastening Through-hole mounting
Type of cable entry M20 x 1.5
Switch type Interlock device without guard interlocking, ISO 14119
Switching principle Slow-action contact
Switching direction Both sides
One side
Approach actuation directions 4 x side (90°)
360°
Approach speed with angle of approach of 15° 0.009 ... 2.5 m/s
Approach speed with angle of approach of 30° 0.008 ... 1.5 m/s
Approach speed with angle of approach of 45° 0.007 ... 1 m/s
Approach speed with angle of approach of 60° 0.007 ... 0.75 m/s
Mechanical life time 20,000,000 actuation cycles, IEC 6047-5-1
Actuation frequency, max. 3,600 per hour, IEC 6047-5-1
Actuator Roll actuator with lever
Actuator width 20 mm
Actuator length 40 mm
Actuation force, min. (torque) 0.1 N·m
Actuator mount Long
Environmental data
Ambient temperature, operation -25 ... 80 °C
Degree of contamination 3, EN 60947-1
Certifications
Degree of protection IP 67
Certifications IMQ
c UL US