RK3C.1/6G Part no.: 50143656
Photoelectric sensors
หมวดหมู่ : Position Sensors ,  Photoelectric sensors , 
แบรนด์ : Leuze
Share
คุณสมบัติ
Basic data
Series                                       3C
Operating principle                     Reflection principle
Application                                Detection of high-gloss or polished surfaces
 Optical data
Operating range                         0.02 ... 6.5 m, With reflector TK(S) 100x100
Operating range limit                   0.02 ... 7 m, With reflector TK(S) 100x100
Light source                               LED, Red
 
Electrical data
Protective circuit                          Polarity reversal protection
                                                Short circuit protected
 Performance data
Supply voltage UB                        10 ... 30 V, DC, Incl. residual ripple
Residual ripple                             0 ... 15 %, From UB
Open-circuit current                      0 ... 20 mA
 Outputs
Number of digital switching outputs            2 Piece(s)
 
Switching output 1
Switching element                           Transistor, Push-pull
Switching principle                           Light switching (PNP)/dark switching (NPN)
 Switching output 2
Switching element                            Transistor, Push-pull
Switching principle                            Dark switching (PNP)/light switching (NPN)
 
Time behavior
Switching frequency                          1,500 Hz
Response time                                  0.33 ms
 
Connection
 
 Connection 1
Type of connection                             Cable
Cable length                                      2,000 mm
Number of conductors                         4 -wire
 
Mechanical data
Dimension (W x H x L)                          11.4 mm x 34.2 mm x 18.3 mm
Housing material                                  Plastic
Plastic housing                                     PC-ABS
Lens cover material                               Plastic / PMMA
Net weight                                          50 g
Type of fastening                                  Through-hole mounting
                                                         Via optional mounting device
Compatibility of materials                        ECOLAB
 Operation and display
Operational controls                             270° potentiometer
 
Environmental data
Ambient temperature, operation             -40 ... 60 °C
 Certifications
Degree of protection                             IP 67... IP 69K
Protection class                                    III
Certifications                                        c UL US
Standards applied                                 IEC 60947-5-2