Electronic pressure sensor
Pressure sensors
หมวดหมู่ : Process sensors ,  Pressure sensors , 
Share
คุณสมบัติ
General information
Range of application                         Liquid and gaseous media
Type of pressure                              Relative pressure
Pressure measuring range min.            0 bar
Pressure measuring range max.           250 bar
Switching frequency                         100 Hz
Bursting pressure                             1000 bar
Pressure resistance                          400 bar
Process connection                          G 1/4
                                                    M 5l
Outputs / inputs
Switching output                            Antivalent: Normally open + normally closed (adjustable)
IO-Link                                         No
 
Electrical data
Operating voltage                          9.6 ... 32 V DC
Voltage type                                 Direct voltage (DC)
Electrical design                            PNP
Current carrying capacity max.         500 mA
Voltage drop max.                         2 V
Current consumption max.               25 mA
Protection class                             III
Short-circuit protection                   Yes
Overload-proof                             Yes
Reverse polarity protection              Yes
Mechanical data
Materials in contact with the medium       V4A (1.4404)
                                                        FPM
Union nut tightening torque                   25 Nm
Minimum number of switching cycles        50 million
Structural length                                  71.6 mm
Material of housing                               PBT
                                                        V4A (1.4404)
                                                        PC
                                                        FPM
Electrical connection                             M12
                                                        4-pin
                                                        Contacts gold-plated
 
Accuracy
Reproducibility                                   < ± 0.5%
Switching point accuracy                      < ± 2.5 %
Linearity deviation                              < ± 1.5 (BFSL)
Ambient conditions
Ambient temperature min.                    -25 °C
Ambient temperature max.                    80 °C
Medium temperature                           -25 ... 80 °C °C
Protection rating                                  IP67