RD800-MSCA-M12R Part no.: 63002010
Safety switches
หมวดหมู่ : Safety technology ,  Safety proximity sensors , 
แบรนด์ : Leuze
Share
คุณสมบัติ
Basic data
Series                                 RD800
Application                          Individual use
                                         Series use
Code type                           Standard code
 Characteristic parameters
SIL                                     Up to 3, IEC 61508
SILCL                                  Up to 3, IEC/EN 62061
Performance Level (PL)           Up to and including e, EN ISO 13849-1
MTTFd                                4,077 years, EN ISO 13849-1
PFHD                                  1.45E-09 per hour
Mission time                         20 years, EN ISO 13849-1
Category                             Up to and including 4, EN ISO 13849
DC                                     High
 Electrical data
Protective circuit                  Cross circuit protection
                                        Short circuit protected
Pulse resistance                   1,500 V
Usage category at DC 12        Ue 24 V, Ie 0.25 A, EN 60947-5-1
 Performance data
Supply voltage UB                24 V, DC, -15 ... 10 %
Current consumption, max.     250 mA
Power consumption, max.       1 W
Nominal current, min.             0.5 mA
Overvoltage category            III
Fuse, external                      1 A
Fuse, internal                       0.75 A polyfuse (O1 + O2 + O3)
Rated insulation voltage         32 V DC
Conventional thermal current, max.     0.25 A
 Inputs
Number of digital switching inputs      2 Piece(s)
 Switching inputs
Type                                  Digital switching input
Switching voltage, typ.           24 V
Voltage type                       DC
Current consumption, max.     5 mA
 Outputs
Number of safety-related switching outputs (OSSDs)     2 Piece(s)
Number of digital switching outputs                          1 Piece(s)
Switching power, max.                                             6 W
 Safety-related switching outputs
Type                                  Safety-related switching output OSSD
Switching voltage, typ.           24 V
Voltage type                       DC
Output current, max.            250 mA
Test-pulse length, max.         0.3 ms
Capacitance, max. between an output and GND    200 nF
Capacitance, max. between two outputs              200 nF
 Safety-related switching output 1
Switching element              Transistor, PNP
 Safety-related switching output 2
Switching element              Transistor, PNP
 Switching outputs
Type                                Digital switching output
Switching voltage, typ.         24 V
Voltage type                     DC
Switching current, max.       100 mA
 Switching output 1
Switching element             Transistor, PNP
Function                          Signal output
 Time behavior
Reaction time after removing the actuator, min.         80 ms
Reaction time after removing the actuator, max.        150 ms
Reaction time after shutdown, input, min.                 7 ms
Reaction time after shutdown, input, max.                12 ms
 Connection
Number of connections       1 Piece(s)
 Connection 1
Function                           Connection with PLC
                                      Signal OUT
                                      Voltage supply
Type of connection             Connector
Thread size                       M12
Material                            Metal
No. of pins                        8 -pin
Plug outlet                        On right side
 Cable properties
Length of connection cable, max.    50 m
 Mechanical data
Design                              Cubic
Dimension (W x H x L)         25 mm x 18 mm x 72 mm
Housing material                 Plastic
Plastic housing                    PA 66
Net weight                         57 g
Housing color                     Black
Type of fastening                Through-hole mounting
Switching hysteresis, max.                  2.4 mm
Assured cut-out distance (Sar), min.     16 mm
Assured cut-in distance (Sao), max.      10 mm
Nominal switch-off distance, max.         14 mm
Nominal operating distance, max.         12 mm
Distance between two systems (sensor, actuator), min.    50 mm
Repeatability, max.                            1.2 mm
Screw tightening torque                    0.8 ... 2 N·m
 Operation and display
Type of display                      LED
Number of LEDs                     4 Piece(s)
 Environmental data
Ambient temperature, operation    -25 ... 70 °C
Ambient temperature, storage       -25 ... 85 °C
Degree of contamination               3, EN 60947-1
 Certifications
Degree of protection             IP 67... IP 69K
Certifications                       TÜV Süd
                                         c UL US
Test procedure for shock in accordance with standard       EN 60068-2-27
Test procedure for vibration in accordance with standard   EN 60068-2-6